Can pulse oximetry or a bedside swallowing assessment be used to detect aspiration after. However, careful interpretation of the pulse oximetry data is necessary in older subjects, smokers, and possibly those with chronic lung disease. If they are the same, you are getting a good signal. The combination of bedside swallowing assessment and oxygen. Describe the significance of the information provided by pulse oximetry. Pulse oximetry is considered a significant technologic advance that has improved patient safety. Measurement of oxygen desaturation is not useful for the detection. A sensor is placed on a thin part of the patients body, usually a fingertip or. Clinical examination, head and neck cancer, swallowing, pulse oximetry, water swallow tests. This study investigated pulse oximetry, bedside swallowing assessment bsa, and videofluoroscopy as tests for detecting aspiration after stroke. However, research regarding validity has been mixed. Screening for aspiration with pulse oximetry what does the. It is an easy, painless measure of how well oxygen is being sent to parts of your body furthest from your heart, such as the arms and legs. Pulse oximetry is a noninvasive method for monitoring a persons oxygen saturation.
Pulse oximetry is a way to measure how much oxygen your blood is carrying. Results for pulse oximetry oxygen saturation dysphagia 1 10 of 19 sorted by relevance date click export csv or ris to download the entire page or use the checkboxes to select a subset of records to download. Pulse oximetry is also being used in the monitoring of pulmonary disease in adults and in the investigation of sleep disorders. Assessment of dyshpagia with the use of pulse oximetry. Nishiwaki k, tsuji t, liu m, hase k, tanaka n, fujiwara t. Pulse oximetry is commonly used to detect hypoxemia and to wean the oxygen concentration in patients undergoing mechanical ventilation. To understand the fluctuation of spo2 on normal swallowing. Two control groups young, fit yf and inpatient age and sexmatched, nonneurological disease ip underwent the same assessment. It monitors the percentage of haemoglobin that is oxygensaturated.
Pulse oximetry 1 pulse oximetry pulse oximeter pulse oximetry or oxymetry in the uk is a noninvasive method allowing the monitoring of the oxygenation of a patients hemoglobin. A sensor is placed on a thin part of the patients body, usually a fingertip or earlobe, or in the case of a neonate, across a foot, and a. Videofluoroscopy findings can be scored with the following. Potential use of pulse oximetry to detect aspiration is attractive to clinicians, as it is readily available, quick, and noninvasive. For 10 weeks all acute stroke as admissions were seen within 48 hours. It is unclear whether pulse oximetry is a clinically viable tool for the detection of dysphagia and aspiration following stroke.
Can pulse oximetry or a bedside swallowing assessment be. Sample nursing assessment form illinois department of. The present study was designed to determine whether bedside pulse oximetry has a role in the assessment of pharyngeal phase dysphagia. Inaccurate pulse oximetry readings may occur when the following factors are present. Can pulse oximetry or a bedside swallowing assessment be used. Describe the use of pulse oximetry with pediatrics. Keep the following in mind when you use a pulse oximeter. A cliplike device called a probe is placed on a body part, such as a finger or ear lobe.
Assessment of swallowing function and muscle using. A quick and accurate initial screening assessment is crucial to decide whether a patient can eat and drink safely. Describe patient conditions that may affect pulse oximetry accuracy. The routine sampling of arterial blood in stable patients whose flo2 has been changed and who are properly monitored with pulse oximetry should be abandoned. Simultaneous pulse oximetry recorded the greatest desaturation from baseline for 10 minutes from. The use of pulse oximetry as a screening assessment for. Assessment of dysphagia with the use of pulse oximetry. Dobyns, in pediatric critical care fourth edition, 2011. Two control groups young, fit yf and inpatient age. Though its reading of peripheral oxygen saturation spo 2 is not always identical to the more desirable reading of arterial oxygen saturation sao 2 from arterial blood gas analysis, the two are correlated well enough that the safe, convenient, noninvasive, inexpensive pulse oximetry method is valuable for.
Oxygen is carried around in your red blood cells by a molecule called haemoglobin. At the childrens hospital of philadelphia, our day surgery nursing staff routinely measures patient vital signs and sp o 2 on the childs arrival to the hospital preoperative registration area approximately 1 h before surgery. Pulse oximetry may provide a useful adjunct to the cbe for dysphagia screening, with average spo2 levels during feeding predicting those with and without dysphagia with moderate levels of. Summary pulse oximeters provide a cheap, quick and non. To make sure the oximeter is giving you a good reading, count your pulse for one minute and compare the number you get to the pulse number on the oximeter. Both modified bsa and pulse oximetry during swallowing showed low sensitivity, specificity and predictive values for the detection of aspiration risk in acute stroke patients compared with. Valve trial and placement additional assessment tools. Oxygen saturation should always be above 95%, although in those with longstanding respiratory disease or cyanotic congenital heart disease, it may be lower, corresponding to disease. Haemoglobin is a protein which is bound to the red blood. Nsw speech pathology evidence based practice interest. Further research is needed to determine whether ultrasonography or videofluoroscopy are valuable tools for determining swallowing function in dysphasic patients. Pulse oximetry assessment nsw speech pathology ebp network.
Methods swallowing was assessed in 189 stroke patients meansd age, 70. We have assessed the measurement of oxygen saturation sao 2 as a means of detecting aspiration in patients with stroke. Pulse oximetry po has been suggested as an option for the. Background and principles of pulse oximetry pulse oximetry is a noninvasive method that enables rapid measurement of the oxygen saturation of hemoglobin in arterial blood. Pulse oximetry is noninvasive without exposure to radiation, is readily portable and widely available, requires minimal patient cooperation, and provides objective quantitative measures. Screening for aspiration with pulse oximetry what does. Patients swallowed 10 ml water while sitting up and sao 2 was noted for 2 minutes.
Pulse oximetry is a test used to measure the oxygen level oxygen saturation of the blood. The practicing speech pathology members of the adult swallowing ebp group wished to explore the evidence for the use of pulse oximetry, as an adjunct to the bedside clinical assessment of the swallow, in. Pulse oximetry is a commonly used means to measure peripheral capillary oxyhemoglobin saturation spo2. He or she requests further swallowing assessment by the slp when he observes signs of swallowing difficulty. Pulse oximetry has numerous advantages in assessing swallowing function if its accuracy in aspiration detection can be proved.
Pulse oximetry measures how much oxygen the haemoglobin in your blood is carrying. During a pulse oximetry reading, a small clamplike device is placed on a finger, earlobe, or toe. Staff swallowing assessment ssa was performed within 24 hours of admission along with pulse oximetry. Apr 02, 2014 pulse oximetry is a simple, relatively cheap and noninvasive technique to monitor oxygenation. The efficiency of the use of pulse oximetry as a tool for examining and or evaluate dysphagia is. Caution should be used when interpreting pulse oximetry readings for patients with chronic lung disease. It has become the standard for continuous, noninvasive assessment of oxygenation and is often considered the fifth vital sign. In hospital respiratory morbidity and mortality, mode of nutrition and disability status at discharge were recorded. Tests to measure your oxygen levels british lung foundation.
Strokes were classified according to brain ct or mri. Principles of oximetry it was discovered in the 1860s that the coloured substance in blood, haemoglobin, was also its carrier of oxygen. Bedside swallowing assessment and saturation assessment at. Methodsswallowing was assessed in 189 stroke patients mean sd age, 70. Pulse oximetry is used routinely in the assessment of young children in neonatal intensive care units and emergency departments and has been proposed as an adjunct to the assessment of the newborn in the delivery room. Physician swallowing screening tends to be less structured than swallowing screening conducted by. Pulse oximetry was less accurate in detecting aspiration than a bedside assessment, except when desaturation of greater then 5% was seen. Fortysix adult patients with clinically suspected swallowing abnormalities underwent modified barium. Division of critical care medicine, the bassett hospital. Swallowing dysfunction in head and neck cancer patients. Pulse oximetry monitoring for the evaluation of swallowing. Instrumental alternative in the clinical evaluation by.
Hospital guidelines for implementing pulse oximetry screening for critical congenital heart disease newborn screening 201 monroe street, suite 50 montgomery, al 363017 phone 18669286755 fax 3342063791. This study investigated pulse oximetry, bedside swallowing assessment bsa, and videofluoroscopy as tests for. See more ideas about pulse oximetry, nursing students and nursing tips. Pulse oximetry does not reliably detect aspiration on. The combination of bedside swallowing assessment and oxygen saturation monitoring of swallowing in acute stroke. Because it is our personal practice in the operating room to immediately remove and discard the dots and paper backing into a waste container before reapplying the pulse oximetry probe, we strongly suspect this infant had ingested the paper cover during the initial assessment in the preoperative registration area. Each subject had initial standard bedside swallowing assessment, closely followed by simultaneous and mutually blinded pulse oximetry, swallowing assessment and videofluoroscopy. Hospital guidelines for implementing pulse oximetry. Identification of a simple screening tool for dysphagia in patients with stroke using factor analysis of multiple dysphagia variables. This is called the oxygen saturation and is a percentage scored out of 100. In conclusion, the present study has demonstrated that pulse oximetry reliably detects aspiration in most dysphagic patients and may be used as an adjunct to the bedside assessment of dysphagia. After sp o 2 measurement, the pulse oximetry probe is removed from the finger or toe and kept with the medical record.
Pulse oximetry is a very useful technology, but there are situations where you must be careful in applying it. In all patients, fiberoptic endoscopic evaluation of swallowing fees was. Anemia damage to red blood cells may cause anem ia, a lack of red bl ood cells and thus 2. Nursing assessment page 1 of 20 sample individual d. Standardized swallowing assessment ssa in acute stroke. Oxygen desaturation on swallowing as a potential marker of. A multiengine electronic search was conducted on 82516 and updated on 4817 in accordance with standards published by the.
Fortysix adult patients with clinically suspected swallowing abnormalities underwent modified barium swallow to evaluate dysphagia. Accuracy of bedside clinical methods compared with fiberoptic endoscopic examination of swallowing fees in determining the risk of aspiration in acute stroke patients. Aug 02, 2017 during a pulse oximetry reading, a small clamplike device is placed on a finger, earlobe, or toe. The physician performs swallowing screening in the course of his or her regular medical evaluation.
Desaturation during swallowing may help to identify aspiration in stroke patients. Screening tests of swallowing function are useful in clinical practice, however, less accurate than videofluoroscopic swallowing study vf and videoendoscopic swallowing study ve. Describe monitoring pulse oximetry during patient assessment. Pulse oximeters are available online or by prescription from your local pharmacy or medical supply company. Some have proposed that aspiration causes reflex bronchoconstriction and a subsequent ventilationperfusion imbalance, which leads to hypoxia and desaturation. The practicing speech pathology members of the adult swallowing ebp group wished to explore the evidence for the use of pulse oximetry, as an adjunct to the bedside clinical assessment of the swallow, in identifying episodes of aspiration including silent aspiration. Tests to check the level of oxygen in your blood can be helpful in diagnosing or monitoring lung disease. Pulse oximetry measures peripheral arterial oxygen saturation spo 2 as a surrogate marker for tissue oxygenation. Nsw speech pathology evidence based practice interest group. Can pulse oximetry or a bedside swallowing assessment be used to detect aspiration after stroke. Pulse oximetry pulse oximetry is a noninvasive method of investigating bedside swallow ramsey, smithard, kalra, 2002. Physician swallowing screening tends to be less structured than swallowing screening conducted by nursing staff. Recent anecdotal literature has shown a relation between arterial oxygen saturation spo2, as measured by pulse oximetry, and aspiration during eating. Pulse oximetry as a screening tool in detecting aspiration.
203 846 194 1573 810 806 172 519 1265 161 388 944 245 566 4 292 1128 922 1516 127 938 17 33 1340 933 1403 1025 1143 854 413 1564 264 1149 1080 1118 1072 1140 1114 144 1015 1366 720 621 510